2 HP Eco Kleer Above Ground Swimming Pool Pump & Motor by Waterway (For Above Ground Pool Only)
The Eco Kleer Pump & Motor is made specifically for above ground swimming pools. It serves to clean pool water so that you may enjoy it all season long, from opening to closing. The Eco Kleer comes in a series of different sizes, each with varying horsepower. The 2 Horsepower version featured here is the largest of the pool pumps available. It is ideal for heavily used swimming pools and large swimming pools. Let a Family Leisure swimming pool expert help you to find the perfect combination of pumps and motors to keep your water crystal clear.
Requirement - 110 Volt / 20 Amp GFCI Protected Outlet
New Installation – Start-Up & Operation prior to pool start-up - Fill strainer housing with water to suction pipe level. NEVER operate without water. Water acts as a coolant and lubricant for the mechanical shaft seal.
Priming - Open all valves before starting system. Release all air from filter and piping system. See filter owner’s manual.
When water source is higher than the pump, it will prime itself when suction and outlet valves are opened. If water source is lower than the pump, unscrew and remove strainer cover; fill strainer and pump with water. Clean and lubricate strainer cover O-ring with "Jack's 327" each time it is removed. Clean and inspect O-ring; re-install on strainer cover. Replace strainer cover on strainer housing; turn clockwise to tighten cover.
NOTE: Tighten strainer cover by hand only (no wrenches) ¼ turn.
Priming time will depend on vertical length of suction lift and horizontal length of suction pipe. If pump does NOT prime within ten minutes, stop motor and determine cause. Be sure all suction and discharge valves are open when running.
Location: MUST be installed below the pool water line (see Figure to right). Self-priming pumps may be installed up to four (4) feet above the pool water line. Install on a firm, level base or pad to meet all local and national codes. The field supplied base or pad must be level and vibration-free. Motors require free circulation of air for cooling. Do NOT install in a damp or non-ventilated location. Though the pump is designed for outdoor use, it is strongly advised to protect the electrical components from the weather. Select a well-drained area, one that will not flood when it rains.
Mounting - Fasten pump to base or pad with screws or bolts to further reduce vibration and stress on pipe or hose joints. The base
MUST be solid - level - rigid - vibration free. Allow inlet height to be as close to water level as possible. Allow use of short, direct suction pipe (to reduce friction losses). Allow for ball valves in suction and outlet piping. Be protected from excess moisture and flooding. Allow adequate access for servicing.
Plumbing - Use Teflon tape to seal threaded connections on molded plastic components. All plastic fittings must be new or thoroughly cleaned before use.
NOTE: Do NOT use Plumber’s Pipe Dope as it may cause cracking of the plastic components. When applying Teflon tape to plastic threads, wrap the entire threaded portion of the male fitting with one to two ayers of tape. Wind the tape clockwise as you face the open end of the fitting, beginning at the end of the fitting. The suction and outlet ports have molded-in thread stops. Do NOT attempt to force hose connector fitting past this stop. It is only necessary to tighten fittings enough to prevent leakage. Tighten fitting by hand and then use a tool to engage fitting an additional 1 ½ turns. Use care when using Teflon tape as friction is reduced considerably; DO NOT over-tighten fitting or you may cause damage. If leaks occur, remove connector, clean off old Teflon tape, rewrap with one to two additional layers of Teflon tape, and re-install connector.
Piping Flexible Hose, PVC, or Reinforced Hose are all acceptable piping methods. For outlet use 1-1/2" PVC pipe or reinforced hose. For suction on ALL models, use 1-1/2" reinforced hose. Increase size if a long run is needed. For pipe larger than port, use reducing fitting in strainer port. To avoid strain, support suction and outlet independently. Place supports near pump. To avoid strain left by a gap at last connection, start all piping at pump and run pipe AWAY. NEVER use suction pipe SMALLER than suction connections. Suction pipe inlet must be lower than inlet port.
Fittings - Fittings restrict flow. For better efficiency, use the fewest possible fittings. Avoid fittings that could cause an air trap. Pool and spa fittings MUST conform to the International Association of Plumbing and Mechanical Officials (IAPMO) standards. Use a non-entrapping suction fitting in pool or double suction (skimmer and main drain).
Voltage - Voltage at motor MUST NOT be more than 10% above or below motor name plate rated voltage, or motor may overheat, causing overload tripping and reduced component life. If voltage is less than 90% or more than 110% of rated voltage when motor is running at full load, consult power company.
Grounding / Bounding - Install, ground, bond, and wire motor according to local or national electrical code requirements. Permanently ground motor. Use green ground terminal provided under motor canopy or access place; use size and type wire required by code. Connect motor ground terminal to electrical service ground. Bond motor to pool structure. Use a solid copper conductor, size or larger. Run wire from external bonding lug to reinforcing rod or mesh. Connect a No. 8 AWG (8.4 mm2) solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of swimming pool, spa, or hottub, and to all electrical equipment, metal piping or conduit within 5 ft. (1.5 m) of inside walls of swimming pool, spa, or hot tub.
Wiring - MUST be permanently connected to circuit. If other lights or appliances are also on the same circuit, be sure to add their amp loads before figuring wire and circuit breaker sizes. (NOTE: If unsure how to do this or if this is confusing, consult a licensed electrician). Use the load circuit breaker as the Master On-Off switch. Install a Ground Fault Circuit Interrupter (GFCI) in circuit; it will sense a short-circuit to ground and disconnect power before it becomes dangerous to pool users. For size of GFCI required and test proceduresfor GFCI, see manufacturer’s instructions.
In case of a power outage, check GFCI for tripping, which will prevent normal operation. Reset if necessary.
NOTE: If you do not use conduit when wiring motor, be sure to seal wire opening on end of motor to prevent dirt, bugs, etc., from entering.
Use Above Ground Pools